Subject overview
Light & Photometry
Luminous intensity, flux, energy, illuminance, luminance and solid angles.
01 Luminous Flux, Energy & Solid Angle
Variables
- luminous flux
- lmlumen
- luminous intensity
- cdcandela
- solid angle
- srsteradian
- luminous energy
- lm slumen second
- elapsed time
- ssecond
- area of spherical patch
- m²square meter
- sphere radius
- mmeter
Key Formulas
Uniform luminous intensity over the specified solid angle. The differential relation dΦ = I dΩ is the local form; total flux requires integration if intensity varies.
Prerequisites: algebra and SI unit conversion.
Input domains: luminous flux: ≥ 0; luminous intensity: ≥ 0; solid angle: 0 ≤ Ω ≤ 4π sr.
Time-independent luminous flux; otherwise Q is the time integral of flux. This is a photometric quantity in lumen seconds, not joules.
Input domains: luminous energy: ≥ 0; luminous flux: ≥ 0; elapsed time: ≥ 0.
A is an area on a sphere centred on the observation point, not an arbitrary planar area. A full sphere has Ω = 4π sr; valid patches cannot exceed the full sphere.
Input domains: solid angle: 0 ≤ Ω ≤ 4π sr; area of spherical patch: ≥ 0; sphere radius: > 0.
Calculate
Numbers or expressions: (), +, -, *, /, ^. Prefixes: 1.5k, 250m, 20u. Results: 3 significant figures. Input help
Enter known quantities; each independent relation is evaluated as soon as it is determined.
Uniform luminous intensity over the specified solid angle. The differential relation dΦ = I dΩ is the local form; total flux requires integration if intensity varies.
Time-independent luminous flux; otherwise Q is the time integral of flux. This is a photometric quantity in lumen seconds, not joules.
A is an area on a sphere centred on the observation point, not an arbitrary planar area. A full sphere has Ω = 4π sr; valid patches cannot exceed the full sphere.
02 Illuminance and Received Flux
Variables
- illuminance
- lxlux
- luminous flux
- lmlumen
- area
- m²square meter
Key Formulas
Mean illuminance over the receiving area; locally E = dΦ/dA. Flux is received flux, not necessarily all emitted flux.
Prerequisites: algebra and SI unit conversion.
Input domains: illuminance: ≥ 0; luminous flux: ≥ 0; area: > 0.
Calculate
Numbers or expressions: (), +, -, *, /, ^. Prefixes: 1.5k, 250m, 20u. Results: 3 significant figures. Input help
Leave one model quantity empty; enter the others to calculate it.
Mean illuminance over the receiving area; locally E = dΦ/dA. Flux is received flux, not necessarily all emitted flux.
03 Inverse-Square Illuminance
Variables
- illuminance
- lxlux
- luminous intensity
- cdcandela
- source-to-receiver distance
- mmeter
Key Formulas
Point source, normal incidence and no absorption. r is the source-to-receiver distance; I is intensity in that direction.
Prerequisites: algebra and SI unit conversion.
Input domains: illuminance: ≥ 0; luminous intensity: ≥ 0; source-to-receiver distance: > 0.
Calculate
Numbers or expressions: (), +, -, *, /, ^. Prefixes: 1.5k, 250m, 20u. Results: 3 significant figures. Input help
Leave one model quantity empty; enter the others to calculate it.
Point source, normal incidence and no absorption. r is the source-to-receiver distance; I is intensity in that direction.
04 Illuminance at Oblique Incidence
Variables
- illuminance
- lxlux
- luminous intensity
- cdcandela
- source-to-receiver distance
- mmeter
- angle from receiving-surface normal
- radradian
Key Formulas
Point source, no absorption; α is measured from the surface normal, 0 ≤ α ≤ π/2. At grazing incidence the received illuminance is zero.
Prerequisites: algebra and SI unit conversion, including trigonometry and inverse sine.
Input domains: illuminance: ≥ 0; luminous intensity: ≥ 0; source-to-receiver distance: > 0; angle from receiving-surface normal: 0 ≤ angle ≤ π/2 rad.
Calculate
Numbers or expressions: (), +, -, *, /, ^. Prefixes: 1.5k, 250m, 20u. Results: 3 significant figures. Input help
Leave one model quantity empty; enter the others to calculate it.
Point source, no absorption; α is measured from the surface normal, 0 ≤ α ≤ π/2. At grazing incidence the received illuminance is zero.
05 Illuminance at Two Distances
Variables
- first illuminance
- lxlux
- first distance
- mmeter
- second illuminance
- lxlux
- second distance
- mmeter
Key Formulas
The same point source and unchanged receiving orientation, without absorption.
Prerequisites: algebra and SI unit conversion.
Input domains: first illuminance: ≥ 0; first distance: > 0; second illuminance: ≥ 0; second distance: > 0.
Calculate
Numbers or expressions: (), +, -, *, /, ^. Prefixes: 1.5k, 250m, 20u. Results: 3 significant figures. Input help
Leave one model quantity empty; enter the others to calculate it.
The same point source and unchanged receiving orientation, without absorption.
06 Luminance
Variables
- luminance
- cd/m²candelas per square meter
- luminous intensity
- cdcandela
- projected emitting area
- m²square meter
- illuminance
- lxlux
- solid angle
- srsteradian
Key Formulas
Uniform luminance over the emitting area projected perpendicular to the viewing direction.
Prerequisites: algebra and SI unit conversion.
Input domains: luminance: ≥ 0; luminous intensity: ≥ 0; projected emitting area: > 0.
Uniform source luminance and paraxial or projected solid angle. For an extended oblique source, E = ∫ L cos θ dΩ; E/Ω is valid only with that projection included.
Input domains: luminance: ≥ 0; illuminance: ≥ 0; solid angle: 0 ≤ Ω ≤ 4π sr.
Calculate
Numbers or expressions: (), +, -, *, /, ^. Prefixes: 1.5k, 250m, 20u. Results: 3 significant figures. Input help
Enter known quantities; each independent relation is evaluated as soon as it is determined.
Uniform luminance over the emitting area projected perpendicular to the viewing direction.
Uniform source luminance and paraxial or projected solid angle. For an extended oblique source, E = ∫ L cos θ dΩ; E/Ω is valid only with that projection included.