Subject overview
Heat Transfer
Temperature differences and steady heat flow through thermal resistance.
01 Thermal Resistance
Variables
- side 1 temperature
- Kkelvin
- side 2 temperature
- Kkelvin
- thermal resistance
- K/Wkelvins per watt
- temperature difference
- Kkelvin interval
- heat flow rate
- Wwatt
Key Formulas
Steady heat flow through a lumped positive thermal resistance. P is positive from side 1 to side 2; negative P means reversed heat flow. ΔT = T₁ − T₂ and P = ΔT/Rth. Radiation, convection and temperature dependence must already be represented by the supplied resistance.
Prerequisites: algebra and SI unit conversion.
Input domains: side 1 temperature: ≥ 0; side 2 temperature: ≥ 0; thermal resistance: > 0.
Calculate
Numbers or expressions: (), +, -, *, /, ^. Prefixes: 1.5k, 250m, 20u. Results: 3 significant figures. Input help
Enter the model inputs to calculate the results.
Steady heat flow through a lumped positive thermal resistance. P is positive from side 1 to side 2; negative P means reversed heat flow. ΔT = T₁ − T₂ and P = ΔT/Rth. Radiation, convection and temperature dependence must already be represented by the supplied resistance.
02 Heat Transfer Rate
Variables
- heat transfer rate
- Wwatt
- heat transferred
- Jjoule
- elapsed time
- ssecond
Key Formulas
Mean heat transfer rate over a positive elapsed interval.
Prerequisites: algebra and SI unit conversion.
Input domains: heat transfer rate: finite real; heat transferred: finite real; elapsed time: ≥ 0.
Calculate
Numbers or expressions: (), +, -, *, /, ^. Prefixes: 1.5k, 250m, 20u. Results: 3 significant figures. Input help
Leave one model quantity empty; enter the others to calculate it.
Mean heat transfer rate over a positive elapsed interval.
03 Heat Carried by a Flow
Variables
- heat transport rate
- Wwatt
- mass flow rate
- kg/skilograms per second
- specific heat capacity
- J/(kg K)joules per kilogram kelvin
- temperature difference
- Kkelvin interval
Key Formulas
Steady sensible-heat transport with constant specific heat and no phase change: Φ = ṁ c ΔT. The printed m·t·c·T expression is dimensionally incorrect; mass flow rate replaces mass times time.
Prerequisites: algebra and SI unit conversion.
Input domains: heat transport rate: finite real; mass flow rate: ≥ 0; specific heat capacity: > 0; temperature difference: finite real.
Calculate
Numbers or expressions: (), +, -, *, /, ^. Prefixes: 1.5k, 250m, 20u. Results: 3 significant figures. Input help
Leave one model quantity empty; enter the others to calculate it.
Steady sensible-heat transport with constant specific heat and no phase change: Φ = ṁ c ΔT. The printed m·t·c·T expression is dimensionally incorrect; mass flow rate replaces mass times time.
04 Solar Irradiance Projection
Variables
- irradiance on receiving surface
- W/m²watts per square meter
- normal irradiance
- W/m²watts per square meter
- angle above receiving surface
- radradian
Key Formulas
Direct-beam geometric projection only; α is measured from the receiving surface, unlike the normal-angle convention in photometry. E₀ is supplied explicitly, not fixed to the source’s historical solar irradiance value. Atmospheric and diffuse radiation are excluded.
Prerequisites: algebra and SI unit conversion, including trigonometry and inverse sine.
Input domains: irradiance on receiving surface: ≥ 0; normal irradiance: > 0; angle above receiving surface: 0 ≤ angle ≤ π/2 rad.
Calculate
Numbers or expressions: (), +, -, *, /, ^. Prefixes: 1.5k, 250m, 20u. Results: 3 significant figures. Input help
Leave one model quantity empty; enter the others to calculate it.
Direct-beam geometric projection only; α is measured from the receiving surface, unlike the normal-angle convention in photometry. E₀ is supplied explicitly, not fixed to the source’s historical solar irradiance value. Atmospheric and diffuse radiation are excluded.
05 Thermal Conduction
Variables
- heat transfer rate
- Wwatt
- thermal conductivity
- W/(m K)watts per meter kelvin
- area
- m²square meter
- temperature difference
- Kkelvin interval
- layer thickness
- mmeter
- heat transferred
- Jjoule
- elapsed time
- ssecond
- layer conductance per unit area
- W/(m² K)watts per square meter kelvin
Key Formulas
Steady one-dimensional conduction through a homogeneous plane layer with constant conductivity and no internal heat generation.
Prerequisites: algebra and SI unit conversion.
Input domains: heat transfer rate: finite real; thermal conductivity: > 0; area: > 0; temperature difference: finite real; layer thickness: > 0.
Constant steady conduction maintained throughout the interval; this also solves the source’s conductivity formula for every quantity.
Input domains: heat transferred: finite real; thermal conductivity: > 0; area: > 0; temperature difference: finite real; elapsed time: ≥ 0; layer thickness: > 0.
k = λ/ℓ is the conductance per area of the solid layer alone. It is not the overall coefficient when finite surface resistances are present.
Input domains: layer conductance per unit area: > 0; thermal conductivity: > 0; layer thickness: > 0.
Calculate
Numbers or expressions: (), +, -, *, /, ^. Prefixes: 1.5k, 250m, 20u. Results: 3 significant figures. Input help
Enter known quantities; each independent relation is evaluated as soon as it is determined.
Steady one-dimensional conduction through a homogeneous plane layer with constant conductivity and no internal heat generation.
Constant steady conduction maintained throughout the interval; this also solves the source’s conductivity formula for every quantity.
k = λ/ℓ is the conductance per area of the solid layer alone. It is not the overall coefficient when finite surface resistances are present.
Mean heat transfer rate over a positive elapsed interval.
06 Heat Transfer at a Surface
Variables
- heat transferred
- Jjoule
- heat transfer coefficient
- W/(m² K)watts per square meter kelvin
- area
- m²square meter
- temperature difference
- Kkelvin interval
- elapsed time
- ssecond
Key Formulas
Newton’s cooling relation with a constant effective heat transfer coefficient and fixed surface-to-fluid temperature difference.
Prerequisites: algebra and SI unit conversion.
Input domains: heat transferred: finite real; heat transfer coefficient: > 0; area: > 0; temperature difference: finite real; elapsed time: ≥ 0.
Calculate
Numbers or expressions: (), +, -, *, /, ^. Prefixes: 1.5k, 250m, 20u. Results: 3 significant figures. Input help
Leave one model quantity empty; enter the others to calculate it.
Newton’s cooling relation with a constant effective heat transfer coefficient and fixed surface-to-fluid temperature difference.
07 Overall Heat Transfer
Variables
- heat transferred
- Jjoule
- overall heat transfer coefficient
- W/(m² K)watts per square meter kelvin
- area
- m²square meter
- temperature difference
- Kkelvin interval
- elapsed time
- ssecond
- first surface heat transfer coefficient
- W/(m² K)watts per square meter kelvin
- second surface heat transfer coefficient
- W/(m² K)watts per square meter kelvin
- thermal conductivity
- W/(m K)watts per meter kelvin
- layer thickness
- mmeter
Key Formulas
Steady one-dimensional heat transfer between two fluids through a wall with fixed overall coefficient. All layers carry the same heat rate; their temperature drops and resistances add.
Prerequisites: algebra and SI unit conversion.
Input domains: heat transferred: finite real; overall heat transfer coefficient: > 0; area: > 0; temperature difference: finite real; elapsed time: ≥ 0.
One homogeneous wall and two finite surface films with equal areas: 1/k = 1/α₁ + ℓ/λ + 1/α₂. The missing ℓ in the source’s overall-resistance formula is restored. Every resistance and coefficient must remain positive.
Input domains: overall heat transfer coefficient: > 0; first surface heat transfer coefficient: > 0; second surface heat transfer coefficient: > 0; thermal conductivity: > 0; layer thickness: > 0.
Calculate
Numbers or expressions: (), +, -, *, /, ^. Prefixes: 1.5k, 250m, 20u. Results: 3 significant figures. Input help
Enter known quantities; each independent relation is evaluated as soon as it is determined.
Steady one-dimensional heat transfer between two fluids through a wall with fixed overall coefficient. All layers carry the same heat rate; their temperature drops and resistances add.
One homogeneous wall and two finite surface films with equal areas: 1/k = 1/α₁ + ℓ/λ + 1/α₂. The missing ℓ in the source’s overall-resistance formula is restored. Every resistance and coefficient must remain positive.